RAID 60 calculator

RAID 60 stripes data across two (or more) RAID 6 groups. Each group can lose any two drives, which makes it the usual choice for large arrays of large drives.

TB

Size printed on the drive label. Different sizes? The array uses the smallest one for every drive.

Advanced settings
MB/s

Typical hard drive: 100–200 MB/s with no other load. SSD: 400 MB/s or more.

From the drive datasheet. It is a worst-case spec, so real drives usually do better.

Show capacity in
128TB usable

Array healthy
Your data Parity or mirror copy Failed drive Click a drive to make it fail.
Drawing12 × 16 TB in RAID 60
Raw192 TB
Efficiency67%

Drives that can fail

Rebuild of one drive

Read error during rebuild

Checks for this setup

The same drives in every RAID level

12 drives of 16 TB each.

LevelUsableEfficiencyDrives that can failRebuildRead error in rebuild
192 TB
100%
None
—
—
16 TB
8%
Any 11
29 h
Fixed by another copy
176 TB
92%
Any 1
29 h
76%
160 TB
83%
Any 2
29 h
Fixed by parity
96 TB
50%
1 to 6
29 h
12%
160 TB
83%
1 to 2
29 h
47%
128 TB
67%
2 to 4
29 h
Fixed by parity

RAID 60 at a glance

Minimum drives8
Usable space(drives − 2 × number of groups) × size of the smallest drive
Drives that can fail2 per group
Read speedHigh
Write speedBetter than one large RAID 6
RebuildReads only the affected group, still protected

How RAID 60 works

The drives are split into spans, each one a RAID 6, and data is striped across the spans. This calculator uses two spans of equal size. Each span gives up two drives to parity.

Usable space (2 spans) = (number of drives − 4) × size of the smallest drive

Why use RAID 60 instead of one big RAID 6?

A single RAID 6 of 20 or 24 large drives reads a huge amount of data in every rebuild, and every drive takes part. Splitting it into two RAID 6 spans halves the data read per rebuild, keeps the other span at full speed and allows up to two failures in each span. The cost is two more drives of parity.

When RAID 60 is used

Large file servers, backup targets and video archives with 12 to 24 or more drives, usually on hardware controllers. With ZFS, the equivalent is a pool of several RAIDZ2 groups.

Questions

What is the minimum number of drives for RAID 60?

Eight: two RAID 6 groups of four drives.

How many drives can fail in RAID 60?

Any two in each group, so up to four if they are spread evenly.

RAID 60 or RAID 6?

Up to about 12 drives, one RAID 6 is simpler and gives more space. Above that, RAID 60 keeps rebuilds shorter.