10 × 24 TB in RAID 10

Usable space, rebuild time and read error risk for 10 drives of 24 TB each.

10 × 24 TB drives in RAID 10 give 120 TB of usable space, which Windows shows as 109.1 TB. 120 TB goes to mirror copies, so 50% of the 240 TB raw space is usable. The array always survives one failed drive. A second failure is survived if it hits a different mirror pair, which a random second failure does 89% of the time.
TB

Size printed on the drive label. Different sizes? The array uses the smallest one for every drive.

Advanced settings
MB/s

Typical hard drive: 100–200 MB/s with no other load. SSD: 400 MB/s or more.

From the drive datasheet. It is a worst-case spec, so real drives usually do better.

Show capacity in
120TB usable

Array healthy
Your data Parity or mirror copy Failed drive Click a drive to make it fail.
Drawing10 × 24 TB in RAID 10
Raw240 TB
Efficiency50%

Drives that can fail

Rebuild of one drive

Read error during rebuild

Checks for this setup

The same drives in every RAID level

10 drives of 24 TB each.

LevelUsableEfficiencyDrives that can failRebuildRead error in rebuild
240 TB
100%
None
—
—
24 TB
10%
Any 9
44 h
Fixed by another copy
216 TB
90%
Any 1
44 h
82%
192 TB
80%
Any 2
44 h
Fixed by parity
120 TB
50%
1 to 5
44 h
17%
192 TB
80%
1 to 2
44 h
54%
144 TB
60%
2 to 4
44 h
Fixed by parity

10 × 24 TB in RAID 10: the numbers

Usable space120 TB (109.1 TB in Windows)
Raw space240 TB
Used for protection120 TB
Efficiency50%
Drives that can fail1 to 5
Rebuild at 150 MB/s44 h
Rebuild at 50 MB/s (busy)5.6 days
Data read during rebuild24 TB
Read error risk, desktop drives85%
Read error risk, NAS drives17%

Rebuild

Replacing a failed drive means writing a full 24 TB drive. At 150 MB/s with no other load that takes about 44 h; on a busy array running at 50 MB/s, about 5.6 days. Only the mirror partner is read, so the other drives are not stressed.

Read errors

Reading 24 TB, the chance of at least one unreadable sector is 85% with desktop drives (1 per 1014 bits) and 17% with NAS drives (1 per 1015). Nothing is left to correct it, so the affected file, or on some controllers the whole rebuild, fails. These are worst-case datasheet rates; real drives usually do better.

Our take

With 10 drives, RAID 6 gives more space (192 TB instead of 120 TB) and survives any two failures. RAID 10 is the better pick for databases and virtual machines that write many small blocks.

Similar setups

All RAID 10 setups

Usable space in TB. Pick a cell for the full numbers.
Drives2 TB4 TB6 TB8 TB10 TB12 TB14 TB16 TB18 TB20 TB22 TB24 TB
4 drives4812162024283236404448
6 drives61218243036424854606672
8 drives81624324048566472808896
10 drives102030405060708090100110120
12 drives1224364860728496108120132144