4 × 16 TB in RAID 10

Usable space, rebuild time and read error risk for 4 drives of 16 TB each.

4 × 16 TB drives in RAID 10 give 32 TB of usable space, which Windows shows as 29.1 TB. 32 TB goes to mirror copies, so 50% of the 64 TB raw space is usable. The array always survives one failed drive. A second failure is survived if it hits a different mirror pair, which a random second failure does 67% of the time.
TB

Size printed on the drive label. Different sizes? The array uses the smallest one for every drive.

Advanced settings
MB/s

Typical hard drive: 100–200 MB/s with no other load. SSD: 400 MB/s or more.

From the drive datasheet. It is a worst-case spec, so real drives usually do better.

Show capacity in
32TB usable

Array healthy
Your data Parity or mirror copy Failed drive Click a drive to make it fail.
Drawing4 × 16 TB in RAID 10
Raw64 TB
Efficiency50%

Drives that can fail

Rebuild of one drive

Read error during rebuild

Checks for this setup

The same drives in every RAID level

4 drives of 16 TB each.

LevelUsableEfficiencyDrives that can failRebuildRead error in rebuild
64 TB
100%
None
—
—
16 TB
25%
Any 3
29 h
Fixed by another copy
48 TB
75%
Any 1
29 h
32%
32 TB
50%
Any 2
29 h
Fixed by parity
32 TB
50%
1 to 2
29 h
12%
Needs at least 6 drives
Needs at least 8 drives

4 × 16 TB in RAID 10: the numbers

Usable space32 TB (29.1 TB in Windows)
Raw space64 TB
Used for protection32 TB
Efficiency50%
Drives that can fail1 to 2
Rebuild at 150 MB/s29 h
Rebuild at 50 MB/s (busy)3.7 days
Data read during rebuild16 TB
Read error risk, desktop drives72%
Read error risk, NAS drives12%

Rebuild

Replacing a failed drive means writing a full 16 TB drive. At 150 MB/s with no other load that takes about 29 h; on a busy array running at 50 MB/s, about 3.7 days. Only the mirror partner is read, so the other drives are not stressed.

Read errors

Reading 16 TB, the chance of at least one unreadable sector is 72% with desktop drives (1 per 1014 bits) and 12% with NAS drives (1 per 1015). Nothing is left to correct it, so the affected file, or on some controllers the whole rebuild, fails. These are worst-case datasheet rates; real drives usually do better.

Our take

With four drives, RAID 6 gives the same 32 TB and survives any two failures. RAID 10 writes faster and rebuilds faster.

Similar setups

All RAID 10 setups

Usable space in TB. Pick a cell for the full numbers.
Drives2 TB4 TB6 TB8 TB10 TB12 TB14 TB16 TB18 TB20 TB22 TB24 TB
4 drives4812162024283236404448
6 drives61218243036424854606672
8 drives81624324048566472808896
10 drives102030405060708090100110120
12 drives1224364860728496108120132144