4 × 4 TB in RAID 10

Usable space, rebuild time and read error risk for 4 drives of 4 TB each.

4 × 4 TB drives in RAID 10 give 8 TB of usable space, which Windows shows as 7.3 TB. 8 TB goes to mirror copies, so 50% of the 16 TB raw space is usable. The array always survives one failed drive. A second failure is survived if it hits a different mirror pair, which a random second failure does 67% of the time.
TB

Size printed on the drive label. Different sizes? The array uses the smallest one for every drive.

Advanced settings
MB/s

Typical hard drive: 100–200 MB/s with no other load. SSD: 400 MB/s or more.

From the drive datasheet. It is a worst-case spec, so real drives usually do better.

Show capacity in
8TB usable

Array healthy
Your data Parity or mirror copy Failed drive Click a drive to make it fail.
Drawing4 × 4 TB in RAID 10
Raw16 TB
Efficiency50%

Drives that can fail

Rebuild of one drive

Read error during rebuild

Checks for this setup

The same drives in every RAID level

4 drives of 4 TB each.

LevelUsableEfficiencyDrives that can failRebuildRead error in rebuild
16 TB
100%
None
—
—
4 TB
25%
Any 3
7 h 24 min
Fixed by another copy
12 TB
75%
Any 1
7 h 24 min
9.2%
8 TB
50%
Any 2
7 h 24 min
Fixed by parity
8 TB
50%
1 to 2
7 h 24 min
3.1%
Needs at least 6 drives
Needs at least 8 drives

4 × 4 TB in RAID 10: the numbers

Usable space8 TB (7.3 TB in Windows)
Raw space16 TB
Used for protection8 TB
Efficiency50%
Drives that can fail1 to 2
Rebuild at 150 MB/s7 h 24 min
Rebuild at 50 MB/s (busy)22 h
Data read during rebuild4 TB
Read error risk, desktop drives27%
Read error risk, NAS drives3.1%

Rebuild

Replacing a failed drive means writing a full 4 TB drive. At 150 MB/s with no other load that takes about 7 h 24 min; on a busy array running at 50 MB/s, about 22 h. Only the mirror partner is read, so the other drives are not stressed.

Read errors

Reading 4 TB, the chance of at least one unreadable sector is 27% with desktop drives (1 per 1014 bits) and 3.1% with NAS drives (1 per 1015). Nothing is left to correct it, so the affected file, or on some controllers the whole rebuild, fails. These are worst-case datasheet rates; real drives usually do better.

Our take

With four drives, RAID 6 gives the same 8 TB and survives any two failures. RAID 10 writes faster and rebuilds faster.

Similar setups

All RAID 10 setups

Usable space in TB. Pick a cell for the full numbers.
Drives2 TB4 TB6 TB8 TB10 TB12 TB14 TB16 TB18 TB20 TB22 TB24 TB
4 drives4812162024283236404448
6 drives61218243036424854606672
8 drives81624324048566472808896
10 drives102030405060708090100110120
12 drives1224364860728496108120132144