4 × 4 TB in RAID 6

Usable space, rebuild time and read error risk for 4 drives of 4 TB each.

4 × 4 TB drives in RAID 6 give 8 TB of usable space, which Windows shows as 7.3 TB. 8 TB goes to parity, so 50% of the 16 TB raw space is usable. The array survives any two failed drives, and it is still protected while one drive rebuilds.
TB

Size printed on the drive label. Different sizes? The array uses the smallest one for every drive.

Advanced settings
MB/s

Typical hard drive: 100–200 MB/s with no other load. SSD: 400 MB/s or more.

From the drive datasheet. It is a worst-case spec, so real drives usually do better.

Show capacity in
8TB usable

Array healthy
Your data Parity or mirror copy Failed drive Click a drive to make it fail.
Drawing4 × 4 TB in RAID 6
Raw16 TB
Efficiency50%

Drives that can fail

Rebuild of one drive

Read error during rebuild

Checks for this setup

The same drives in every RAID level

4 drives of 4 TB each.

LevelUsableEfficiencyDrives that can failRebuildRead error in rebuild
16 TB
100%
None
—
—
4 TB
25%
Any 3
7 h 24 min
Fixed by another copy
12 TB
75%
Any 1
7 h 24 min
9.2%
8 TB
50%
Any 2
7 h 24 min
Fixed by parity
8 TB
50%
1 to 2
7 h 24 min
3.1%
Needs at least 6 drives
Needs at least 8 drives

4 × 4 TB in RAID 6: the numbers

Usable space8 TB (7.3 TB in Windows)
Raw space16 TB
Used for protection8 TB
Efficiency50%
Drives that can failAny 2
Rebuild at 150 MB/s7 h 24 min
Rebuild at 50 MB/s (busy)22 h
Data read during rebuild12 TB
Read error risk, desktop drives62% (corrected)
Read error risk, NAS drives9.2% (corrected)

Rebuild

Replacing a failed drive means writing a full 4 TB drive. At 150 MB/s with no other load that takes about 7 h 24 min; on a busy array running at 50 MB/s, about 22 h. The rebuild reads every surviving drive: 12 TB in total.

Read errors

Reading 12 TB, the chance of at least one unreadable sector is 62% with desktop drives (1 per 1014 bits) and 9.2% with NAS drives (1 per 1015). The second parity corrects it, so the rebuild finishes without losing data.

Our take

With four drives, RAID 6 and RAID 10 both give 8 TB. RAID 6 survives any two failures; RAID 10 writes and rebuilds faster. With 4 TB drives, RAID 5 would give 12 TB with a rebuild of 7 h 24 min. RAID 6 is still the safer choice for data you cannot replace.

Similar setups

All RAID 6 setups

Usable space in TB. Pick a cell for the full numbers.
Drives2 TB4 TB6 TB8 TB10 TB12 TB14 TB16 TB18 TB20 TB22 TB24 TB
4 drives4812162024283236404448
5 drives61218243036424854606672
6 drives81624324048566472808896
7 drives102030405060708090100110120
8 drives1224364860728496108120132144
10 drives163248648096112128144160176192
12 drives20406080100120140160180200220240