5 × 22 TB in RAID 5: the numbers
| Usable space | 88 TB (80 TB in Windows) |
|---|---|
| Raw space | 110 TB |
| Used for protection | 22 TB |
| Efficiency | 80% |
| Drives that can fail | Any 1 |
| Rebuild at 150 MB/s | 40 h |
| Rebuild at 50 MB/s (busy) | 5.1 days |
| Data read during rebuild | 88 TB |
| Read error risk, desktop drives | over 99% |
| Read error risk, NAS drives | 51% |
Rebuild
Replacing a failed drive means writing a full 22 TB drive. At 150 MB/s with no other load that takes about 40 h; on a busy array running at 50 MB/s, about 5.1 days. The rebuild reads every surviving drive: 88 TB in total.
Read errors
Reading 88 TB, the chance of at least one unreadable sector is over 99% with desktop drives (1 per 1014 bits) and 51% with NAS drives (1 per 1015). Nothing is left to correct it, so the affected file, or on some controllers the whole rebuild, fails. These are worst-case datasheet rates; real drives usually do better.
Our take
With 22 TB drives we would pick RAID 6. 6 drives in RAID 6 give the same 88 TB and survive two failures, or a read error during a rebuild. Keeping 5 drives, RAID 6 gives 66 TB.