7 × 6 TB in RAID 5

Usable space, rebuild time and read error risk for 7 drives of 6 TB each.

7 × 6 TB drives in RAID 5 give 36 TB of usable space, which Windows shows as 32.7 TB. 6 TB goes to parity, so 86% of the 42 TB raw space is usable. The array survives one failed drive. A second failure, or an unreadable sector, before the rebuild ends can lose data.
TB

Size printed on the drive label. Different sizes? The array uses the smallest one for every drive.

Advanced settings
MB/s

Typical hard drive: 100–200 MB/s with no other load. SSD: 400 MB/s or more.

From the drive datasheet. It is a worst-case spec, so real drives usually do better.

Show capacity in
36TB usable

Array healthy
Your data Parity or mirror copy Failed drive Click a drive to make it fail.
Drawing7 × 6 TB in RAID 5
Raw42 TB
Efficiency86%

Drives that can fail

Rebuild of one drive

Read error during rebuild

Checks for this setup

The same drives in every RAID level

7 drives of 6 TB each.

LevelUsableEfficiencyDrives that can failRebuildRead error in rebuild
42 TB
100%
None
—
—
6 TB
14%
Any 6
11 h
Fixed by another copy
36 TB
86%
Any 1
11 h
25%
30 TB
71%
Any 2
11 h
Fixed by parity
RAID 10 +1 spare
18 TB
43%
1 to 3
11 h
4.7%
RAID 50 +1 spare
24 TB
57%
1 to 2
11 h
9.2%
Needs at least 8 drives

7 × 6 TB in RAID 5: the numbers

Usable space36 TB (32.7 TB in Windows)
Raw space42 TB
Used for protection6 TB
Efficiency86%
Drives that can failAny 1
Rebuild at 150 MB/s11 h
Rebuild at 50 MB/s (busy)33 h
Data read during rebuild36 TB
Read error risk, desktop drives94%
Read error risk, NAS drives25%

Rebuild

Replacing a failed drive means writing a full 6 TB drive. At 150 MB/s with no other load that takes about 11 h; on a busy array running at 50 MB/s, about 33 h. The rebuild reads every surviving drive: 36 TB in total.

Read errors

Reading 36 TB, the chance of at least one unreadable sector is 94% with desktop drives (1 per 1014 bits) and 25% with NAS drives (1 per 1015). Nothing is left to correct it, so the affected file, or on some controllers the whole rebuild, fails. These are worst-case datasheet rates; real drives usually do better.

Our take

With 7 drives sharing one parity, a second failure during the rebuild gets more likely. RAID 6 gives 30 TB with two-drive protection.

Similar setups

All RAID 5 setups

Usable space in TB. Pick a cell for the full numbers.
Drives2 TB4 TB6 TB8 TB10 TB12 TB14 TB16 TB18 TB20 TB22 TB24 TB
3 drives4812162024283236404448
4 drives61218243036424854606672
5 drives81624324048566472808896
6 drives102030405060708090100110120
7 drives1224364860728496108120132144
8 drives14284256708498112126140154168