3 × 22 TB in RAID 5

Usable space, rebuild time and read error risk for 3 drives of 22 TB each.

3 × 22 TB drives in RAID 5 give 44 TB of usable space, which Windows shows as 40 TB. 22 TB goes to parity, so 67% of the 66 TB raw space is usable. The array survives one failed drive. A second failure, or an unreadable sector, before the rebuild ends can lose data.
TB

Size printed on the drive label. Different sizes? The array uses the smallest one for every drive.

Advanced settings
MB/s

Typical hard drive: 100–200 MB/s with no other load. SSD: 400 MB/s or more.

From the drive datasheet. It is a worst-case spec, so real drives usually do better.

Show capacity in
44TB usable

Array healthy
Your data Parity or mirror copy Failed drive Click a drive to make it fail.
Drawing3 × 22 TB in RAID 5
Raw66 TB
Efficiency67%

Drives that can fail

Rebuild of one drive

Read error during rebuild

Checks for this setup

The same drives in every RAID level

3 drives of 22 TB each.

LevelUsableEfficiencyDrives that can failRebuildRead error in rebuild
66 TB
100%
None
—
—
22 TB
33%
Any 2
40 h
Fixed by another copy
44 TB
67%
Any 1
40 h
30%
Needs at least 4 drives
Needs at least 4 drives
Needs at least 6 drives
Needs at least 8 drives

3 × 22 TB in RAID 5: the numbers

Usable space44 TB (40 TB in Windows)
Raw space66 TB
Used for protection22 TB
Efficiency67%
Drives that can failAny 1
Rebuild at 150 MB/s40 h
Rebuild at 50 MB/s (busy)5.1 days
Data read during rebuild44 TB
Read error risk, desktop drives97%
Read error risk, NAS drives30%

Rebuild

Replacing a failed drive means writing a full 22 TB drive. At 150 MB/s with no other load that takes about 40 h; on a busy array running at 50 MB/s, about 5.1 days. The rebuild reads every surviving drive: 44 TB in total.

Read errors

Reading 44 TB, the chance of at least one unreadable sector is 97% with desktop drives (1 per 1014 bits) and 30% with NAS drives (1 per 1015). Nothing is left to correct it, so the affected file, or on some controllers the whole rebuild, fails. These are worst-case datasheet rates; real drives usually do better.

Our take

With 22 TB drives we would pick RAID 6. 4 drives in RAID 6 give the same 44 TB and survive two failures, or a read error during a rebuild.

Similar setups

All RAID 5 setups

Usable space in TB. Pick a cell for the full numbers.
Drives2 TB4 TB6 TB8 TB10 TB12 TB14 TB16 TB18 TB20 TB22 TB24 TB
3 drives4812162024283236404448
4 drives61218243036424854606672
5 drives81624324048566472808896
6 drives102030405060708090100110120
7 drives1224364860728496108120132144
8 drives14284256708498112126140154168