8 × 4 TB in RAID 5

Usable space, rebuild time and read error risk for 8 drives of 4 TB each.

8 × 4 TB drives in RAID 5 give 28 TB of usable space, which Windows shows as 25.5 TB. 4 TB goes to parity, so 88% of the 32 TB raw space is usable. The array survives one failed drive. A second failure, or an unreadable sector, before the rebuild ends can lose data.
TB

Size printed on the drive label. Different sizes? The array uses the smallest one for every drive.

Advanced settings
MB/s

Typical hard drive: 100–200 MB/s with no other load. SSD: 400 MB/s or more.

From the drive datasheet. It is a worst-case spec, so real drives usually do better.

Show capacity in
28TB usable

Array healthy
Your data Parity or mirror copy Failed drive Click a drive to make it fail.
Drawing8 × 4 TB in RAID 5
Raw32 TB
Efficiency88%

Drives that can fail

Rebuild of one drive

Read error during rebuild

Checks for this setup

The same drives in every RAID level

8 drives of 4 TB each.

LevelUsableEfficiencyDrives that can failRebuildRead error in rebuild
32 TB
100%
None
—
—
4 TB
13%
Any 7
7 h 24 min
Fixed by another copy
28 TB
88%
Any 1
7 h 24 min
20%
24 TB
75%
Any 2
7 h 24 min
Fixed by parity
16 TB
50%
1 to 4
7 h 24 min
3.1%
24 TB
75%
1 to 2
7 h 24 min
9.2%
16 TB
50%
2 to 4
7 h 24 min
Fixed by parity

8 × 4 TB in RAID 5: the numbers

Usable space28 TB (25.5 TB in Windows)
Raw space32 TB
Used for protection4 TB
Efficiency88%
Drives that can failAny 1
Rebuild at 150 MB/s7 h 24 min
Rebuild at 50 MB/s (busy)22 h
Data read during rebuild28 TB
Read error risk, desktop drives89%
Read error risk, NAS drives20%

Rebuild

Replacing a failed drive means writing a full 4 TB drive. At 150 MB/s with no other load that takes about 7 h 24 min; on a busy array running at 50 MB/s, about 22 h. The rebuild reads every surviving drive: 28 TB in total.

Read errors

Reading 28 TB, the chance of at least one unreadable sector is 89% with desktop drives (1 per 1014 bits) and 20% with NAS drives (1 per 1015). Nothing is left to correct it, so the affected file, or on some controllers the whole rebuild, fails. These are worst-case datasheet rates; real drives usually do better.

Our take

With 8 drives sharing one parity, a second failure during the rebuild gets more likely. RAID 6 gives 24 TB with two-drive protection. RAID 10 with the same drives gives 16 TB, faster writes and shorter rebuilds.

Similar setups

All RAID 5 setups

Usable space in TB. Pick a cell for the full numbers.
Drives2 TB4 TB6 TB8 TB10 TB12 TB14 TB16 TB18 TB20 TB22 TB24 TB
3 drives4812162024283236404448
4 drives61218243036424854606672
5 drives81624324048566472808896
6 drives102030405060708090100110120
7 drives1224364860728496108120132144
8 drives14284256708498112126140154168