4 × 22 TB in RAID 6

Usable space, rebuild time and read error risk for 4 drives of 22 TB each.

4 × 22 TB drives in RAID 6 give 44 TB of usable space, which Windows shows as 40 TB. 44 TB goes to parity, so 50% of the 88 TB raw space is usable. The array survives any two failed drives, and it is still protected while one drive rebuilds.
TB

Size printed on the drive label. Different sizes? The array uses the smallest one for every drive.

Advanced settings
MB/s

Typical hard drive: 100–200 MB/s with no other load. SSD: 400 MB/s or more.

From the drive datasheet. It is a worst-case spec, so real drives usually do better.

Show capacity in
44TB usable

Array healthy
Your data Parity or mirror copy Failed drive Click a drive to make it fail.
Drawing4 × 22 TB in RAID 6
Raw88 TB
Efficiency50%

Drives that can fail

Rebuild of one drive

Read error during rebuild

Checks for this setup

The same drives in every RAID level

4 drives of 22 TB each.

LevelUsableEfficiencyDrives that can failRebuildRead error in rebuild
88 TB
100%
None
—
—
22 TB
25%
Any 3
40 h
Fixed by another copy
66 TB
75%
Any 1
40 h
41%
44 TB
50%
Any 2
40 h
Fixed by parity
44 TB
50%
1 to 2
40 h
16%
Needs at least 6 drives
Needs at least 8 drives

4 × 22 TB in RAID 6: the numbers

Usable space44 TB (40 TB in Windows)
Raw space88 TB
Used for protection44 TB
Efficiency50%
Drives that can failAny 2
Rebuild at 150 MB/s40 h
Rebuild at 50 MB/s (busy)5.1 days
Data read during rebuild66 TB
Read error risk, desktop drives99% (corrected)
Read error risk, NAS drives41% (corrected)

Rebuild

Replacing a failed drive means writing a full 22 TB drive. At 150 MB/s with no other load that takes about 40 h; on a busy array running at 50 MB/s, about 5.1 days. The rebuild reads every surviving drive: 66 TB in total.

Read errors

Reading 66 TB, the chance of at least one unreadable sector is 99% with desktop drives (1 per 1014 bits) and 41% with NAS drives (1 per 1015). The second parity corrects it, so the rebuild finishes without losing data.

Our take

With four drives, RAID 6 and RAID 10 both give 44 TB. RAID 6 survives any two failures; RAID 10 writes and rebuilds faster. For 22 TB drives this is the setup most administrators would choose: the rebuild takes 40 h, and the array stays protected the whole time.

Similar setups

All RAID 6 setups

Usable space in TB. Pick a cell for the full numbers.
Drives2 TB4 TB6 TB8 TB10 TB12 TB14 TB16 TB18 TB20 TB22 TB24 TB
4 drives4812162024283236404448
5 drives61218243036424854606672
6 drives81624324048566472808896
7 drives102030405060708090100110120
8 drives1224364860728496108120132144
10 drives163248648096112128144160176192
12 drives20406080100120140160180200220240