5 × 10 TB in RAID 6: the numbers
| Usable space | 30 TB (27.3 TB in Windows) |
|---|---|
| Raw space | 50 TB |
| Used for protection | 20 TB |
| Efficiency | 60% |
| Drives that can fail | Any 2 |
| Rebuild at 150 MB/s | 18 h |
| Rebuild at 50 MB/s (busy) | 2.3 days |
| Data read during rebuild | 40 TB |
| Read error risk, desktop drives | 96% (corrected) |
| Read error risk, NAS drives | 27% (corrected) |
Rebuild
Replacing a failed drive means writing a full 10 TB drive. At 150 MB/s with no other load that takes about 18 h; on a busy array running at 50 MB/s, about 2.3 days. The rebuild reads every surviving drive: 40 TB in total.
Read errors
Reading 40 TB, the chance of at least one unreadable sector is 96% with desktop drives (1 per 1014 bits) and 27% with NAS drives (1 per 1015). The second parity corrects it, so the rebuild finishes without losing data.
Our take
For 10 TB drives this is the setup most administrators would choose: the rebuild takes 18 h, and the array stays protected the whole time.